This manual provides installation, plumbing, gas connection, and maintenance instructions for the Dux Prodigy 3 H1250 1250 Rev. I gas hot water heater.
This document is the Owner's Manual for the Dux Prodigy 3 H1250 1250 Rev. I gas hot water heater. It covers installation details, including outdoor tank placement and plumbing connections, as well as specific instructions for units fitted with Robertshaw or Eurosit gas controllers. The manual includes safety warnings, commissioning adjustments, and troubleshooting guides.
| Capacity (L) | 135 / 170 |
|---|---|
| Net Weight Empty (kg) | 72 / 86 |
| Relief Valve Pressure (kPA) | 1400 |
| Water Capacity in First Hour (L) | 270 / 305 |
| Gas Consumption (135SN) | 33 MJ/h |
| Gas Consumption (135SL) | 29 MJ/h |
| Gas Consumption (170SN) | 33 MJ/h |
| Gas Consumption (170SL) | 29 MJ/h |
| Height (mm) | 1601 / 1896 |
The water heater is designed for direct connection to water supply pressures of no greater than 1120kPa.
The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years, or less in areas where local regulations apply.
No, this water heater must not be used for pool heating.
The valve rating is 1400kPa for all models.