DURTOX electrochemical detectors detect toxic gases and oxygen with RS485 or 4-20mA formats, featuring auto-zero, thermal compensation, and IP65 protection.
DURTOX detectors use electrochemical technology to detect toxic gases and oxygen in environments like labs and pharmaceutical facilities. They are available in RS485 and 4-20mA formats, with features including auto-zero adjustment, thermal compensation, and digital filtering. The detectors are IP65 rated and include a 12-bit microprocessor for precise control. Applications cover gases like H2S, NH3, NO2, O2, NO, Cl2, and SO2 with specified ranges and installation heights.
The product is designed for use with DURGAS and EUROSONDELCO control panels, with optional relay outputs. Technical specs include 10–15V DC power, ±2-year sensor life, and response times from 15s to 60s depending on gas. Installation distance up to 1000m, dimensions 125x150x63mm, and weight 300g. This manual is written in Spanish.
| Technology | 12bit Microprocessor and electrochemical sensor |
|---|---|
| Power | 10 to 15V DC |
| Maximum Consumption | approx. 43mA at 12V DC |
| Useful Life | ± 2 years (in clear air) |
| Resolution | 1 ppm CO, 2 ppm NH3, 0,1 ppm NO2, H2S, Cl2, SO2, 0,5 ppm NO, and 2% O2 |
| Stabilization Delay | Approx. 5 minutes |
| Temperature Range | -10ºC to +50ºC |
| Humidity Range | 20-90% RH |
| Working Pressure | 90-110 KPa |
| Protection Grade | IP65 |
| Alarm Relay | Switched output dry contact 3A 250V AC fuse protected |
| Cable Type | 4 wire shielded (power 2 x 1,5 + 2 x 0,25 twisted pair A and B communications) RS485 |
| Maximum Installation Distance | 1000m |
| Dimensions | 125 x 150 x 63 mm |
| Weight | 300g |
DURTOX detectors detect H2S, NH3, NO2, O2, NO, Cl2, and SO2.
DURTOX detectors are available in RS485 addressable 4-wire and 3-wire 4-20mA formats.
DURTOX detectors are guaranteed against manufacturing defects for 1 year from the date of purchase.
Response times vary: SO2 and NH3 ≤30s, H2S ≤20s, O2 ≤15s, NO ≤40s, Cl2 ≤60s, NO2 ≤20s.