Duran Electronica DIREX-X infrared flameproof detector for explosive gases, CO2 and N2O with ATEX-certified housing and technical specifications.
The DIREX-X is an infrared flameproof detector for explosive gases, CO2 and N2O, with a flameproof housing for use in explosive gas atmospheres and a version certified for explosive dust atmospheres. It is intended for applications such as livestock installations, atmospheres with inhibitor or poisonous gases for catalytic detectors, oxygen-deficient atmospheres, and installations where maintenance must be minimized.
Available formats include RS485 addressable 4-wire and 4-20mA 3-wire connections, with factory calibration, optional alarm relay outputs, and a recommended revision interval of at least every 3 years. The leaflet also lists technical characteristics, installation guidance, warranty terms, and order codes.
| Supply voltage | From 10V to 30V DC |
|---|---|
| Maximum consumption | 80mA at 12V DC / 100mA activated relay |
| Maximum loop resistance | 250 ohm (4-20mA) |
| Maximum output current | 21.3 mA (4-20mA) |
| Loop fault current | Less than 2mA (4-20mA) |
| Explosive gases measurement range | 0-100% L.E.L. |
| CO2 measurement range | 0-20,000 ppm (0-2% v/v) |
| N2O measurement range | 0-1,000 ppm |
| Resolution | Explosive gases >0.5% L.E.L.; CO2 >1.2% of measurement range; N2O >2% of measurement range |
| Zero drift | Explosive gases ±3% L.E.L. max/year at 20 C; CO2 ±0.7%/year; N2O ±1% F.S./year |
| Span drift | Explosive gases ±3% L.E.L./year at 20 C; CO2 ±0.7% F.S./year; N2O ±1% F.S./year |
| Stabilisation time | Less than 30 min |
| Resistance to H2S | Yes, totally immune |
| Response time | T50/T90 less than 15s and 30s respectively |
| Useful life (MTBF) | Greater than 5 years |
| Maintenance period | Every 3 years (recommended) |
| Temperature range | -20 C to +50 C |
| Humidity range | 0 to 95% RH, no condensation |
| Atmospheric pressure limit | 80 to 110 kPa (0.8 to 1.1 bar) |
| Protection grade | IP65 |
| Box material | Aluminium / stainless steel |
| Explosive atmosphere code | Ex db IIC T6 Gb / Ex tb IIIC T85 C Db |
| ATEX certificate | LOM 08ATEX2059 X |
| Dimensions | 155 x 180 x 110 mm |
| Weight | Approximately 1,700 g |
| Warranty | 1 year from date of purchase |
No, the detectors are factory-calibrated with span gas and do not require recalibration during initial startup.
They should be revised at least once every 3 years.
It detects explosive gases (methane, natural gas, and propane), CO2, and N2O.
They are guaranteed against manufacturing defects for 1 year from the date of purchase.