Installation guide for Digital Monitoring Products XR150/XR550 series security panels, covering power, communication, zone expansion, and wiring.
This guide provides step-by-step instructions for installing Digital Monitoring Products' XR150/XR550 series security panels. It covers power supply configurations, communication options including encrypted and cellular connections, panel zone setup, and wiring for keypad and bus devices. The document also includes compliance and safety notes for proper installation.
The XR150/XR550 panels support up to 16 supervised keypads, LX-Bus and AX-Bus expansion, and multiple output types including SPDT relays and open collector outputs. It includes detailed diagrams and specifications for transformers, battery systems, and enclosure types. Optional modules like Wi-Fi and cellular can be added for enhanced connectivity. This manual is written in Chinese.
| Transformer Input (Model 327) | Primary input: 120 VAC, 60 Hz, Secondary output: 16.5 VAC 50 VA |
|---|---|
| Standby Battery | 12 VDC, 1.0 Amps Max. charging current on Models 364, 365, 366, 368, or 369 |
| Communication | Built-in network communication to DMP Model SCS-1R or SCS-VR Receivers |
| Panel Zones | Eight 1k or 2.2k Ohm EOL burglary zones (zones 1 to 8) |
| Keypad Bus | Up to 16 supervised keypads and expansion modules |
| Enclosure Model 350 | 17.5”W x 13.5”H x 3.5”D Gray (G) or Red (R) 18-Gauge |
The XR150/XR550 series supports eight on-board burglary zones and two on-board powered zones, with additional zone expansion via keypad bus and LX-Bus up to 16 zones.
You can connect up to a total of 16 supervised keypads and expansion modules.
The bell output is 12 VDC at 1.5 Amp Max.
The 350A enclosure is 17.5”W x 13.5”H x 3.75”D.