This guide provides instructions for installing the Dialogic EDP-10 EdgeMedia DSP Processor Array board in a compatible IP Media Server.
The document details the installation procedure for the EdgeMedia DSP Processor Array (EDP-10) plug-in board, which is required to provide transcoding assistance for non-G.711 networks such as G.726 or G.729 within a Dialogic IP Media Server.
It covers operating and environmental specifications including power requirements, temperature limits, and cooling needs. The guide also explains how to recognize compatible PCI slots, describes the function of the board's status LEDs (ON/UP, Active, Ingress Traffic, Egress Traffic), and outlines safety compliance statements regarding grounding and static electricity.
| Power Requirements (Base) | 2A at 5VDC = 10W / 4A at 3.3VDC = 13.2W |
|---|---|
| Operating Temperature | 0 degree C - 50 degree C |
| Humidity Range | 10% - 95% (noncondensing) |
| Cooling Requirement | Direct forced-air flow is required. |
| MTBF (Mean Time Between Failures) | >150,000 hours |
The board provides transcoding assistance for non-G.711 networks such as G.726 or G.729.
The base requires 2A at 5VDC (10W) and 4A at 3.3VDC (13.2W).
The ON/UP LED is on when the card is powered on, out of reset, and ready to be used.