The DESCO EMIT 50601 Bench Top Ionizer BTI manual provides setup, operation, and maintenance instructions for the AC corona ionizer.
About this manual
This manual describes the DESCO EMIT Bench Top Ionizer BTI (model 50601), a bench‑top ionizer that uses AC corona discharge to generate positive and negative ions for static discharge. It includes a patented Faraday‑cylinder balance device to keep ion output within ±5 V and can be placed on a workbench or hung, covering a static‑neutralising range of 150‑1000 mm.
The document explains how to install the unit, select airflow, and operate it safely—emphasising proper grounding. It also details routine maintenance procedures such as brush cleaning every six months, annual compressed‑air cleaning, and periodic inspection to keep ion balance and ozone emission (<0.05 PPM) within specifications. This manual is written in Chinese.
What's inside
- Product Overview
- Installation and Operation
- Maintenance
- Specifications
Specifications
| Input Power | 220 V, 50/60 Hz, 1.5 A |
|---|
| Output Voltage | 4.5 kV, 50‑60 nA |
|---|
| Air Flow | 0‑117 CFM |
|---|
| Ion Balance | ±5 V |
|---|
| Dimensions | 11" × 9" × 7" |
|---|
| Ozone Emission | <0.05 PPM |
Frequently asked questions
How often should the ionizer be maintained?
The ionizer should be cleaned with the supplied brush every six months, with an additional compressed‑air cleaning once a year, and periodic inspection of the ion needle.
Where should the ionizer be installed?
Place the BTI ionizer on a suitable bench surface or hang it, ensuring it is within the 150‑1000 mm static‑neutralising range and properly grounded.
What is the ozone emission level of the ionizer?
The device emits less than 0.05 PPM ozone.