DESCO EMIT 50601 Bench Top Ionizer User Manual

The DESCO EMIT 50601 Bench Top Ionizer BTI manual provides setup, operation, and maintenance instructions for the AC corona ionizer.


DESCO EMIT 50601 Bench Top Ionizer User Manual - cover page
Brand
Desco EMIT
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
3
File format
PDF
File size
770 KB
Published
01 October, 2026
Updated
01 October, 2026
MD5 checksum
48F80837F4CE2911CD2ADFBC2A27DC77

About this manual

This manual describes the DESCO EMIT Bench Top Ionizer BTI (model 50601), a bench‑top ionizer that uses AC corona discharge to generate positive and negative ions for static discharge. It includes a patented Faraday‑cylinder balance device to keep ion output within ±5 V and can be placed on a workbench or hung, covering a static‑neutralising range of 150‑1000 mm.

The document explains how to install the unit, select airflow, and operate it safely—emphasising proper grounding. It also details routine maintenance procedures such as brush cleaning every six months, annual compressed‑air cleaning, and periodic inspection to keep ion balance and ozone emission (<0.05 PPM) within specifications. This manual is written in Chinese.

What's inside

  • Product Overview
  • Installation and Operation
  • Maintenance
  • Specifications

Specifications

Input Power220 V, 50/60 Hz, 1.5 A
Output Voltage4.5 kV, 50‑60 nA
Air Flow0‑117 CFM
Ion Balance±5 V
Dimensions11" × 9" × 7"
Ozone Emission<0.05 PPM

Frequently asked questions

How often should the ionizer be maintained?

The ionizer should be cleaned with the supplied brush every six months, with an additional compressed‑air cleaning once a year, and periodic inspection of the ion needle.

Where should the ionizer be installed?

Place the BTI ionizer on a suitable bench surface or hang it, ensuring it is within the 150‑1000 mm static‑neutralising range and properly grounded.

What is the ozone emission level of the ionizer?

The device emits less than 0.05 PPM ozone.