De Neef IP 1C-Manual Hand Pump Technical Data Sheet

De Neef IP 1C-Manual hand pump technical data sheet for polyurethane and epoxy resin injection up to 100 bar.


De Neef IP 1C-Manual Hand Pump Technical Data Sheet - cover page
Brand
De Neef
Category
Industrial Supply
Document type
Product Leaflet
Language
Dutch
Pages
3
File format
PDF
File size
84 KB
Published
21 November, 2026
Updated
21 November, 2026
MD5 checksum
66496C57B786E93CDA3375481AA17BF3

About this manual

The De Neef IP 1C-Manual is a hand-driven pump with a single piston for resin injections. It is designed for 1-component polyurethane resins and 2-component epoxy resins with low or medium-high viscosity, and can also be used with premixed 2-component resins or epoxy resins with long pot life.

The pump is intended for smaller injection work at pressures up to 100 bar and is supplied in an anodized finish, mounted on a base, with a 3 m pressure hose. The document also covers storage, advantages, application steps, cleaning, and safety precautions for use. This manual is written in Dutch.

What's inside

  • Use
  • Description
  • Technical Data
  • Appearance
  • Packaging
  • Storage
  • Accessories
  • Advantages
  • Application
  • Safety and Health

Specifications

DriveHand pump
Working pressure0-100 bar
Maximum pressure100 bar
DimensionsL 114 cm x D 38 cm x H 55 cm
Weight15 kg
FinishAnodized
Pressure hose3 m
PackagingOn pallet

Frequently asked questions

What resins can the De Neef IP 1C-Manual hand pump be used with?

It is designed for 1-component polyurethane resins and 2-component epoxy resins with low or medium-high viscosity, and can also be used with premixed 2-component resins or epoxy resins with long pot life.

What is the maximum injection pressure of the pump?

The pump can be used for injection work at pressures up to 100 bar.

How should the pump be cleaned after injection?

After injecting, clean the pump immediately with Washing Agent Eco, remove solvent from the pump and pressure hose, dismantle it to check the piston and balls, clean valve balls and seats if needed, replace the o-ring daily, reassemble it, and test it with Washing Agent Eco.

What safety precautions are given for using the pump?

Never point the injection gun at a body part, use only original spare parts, and allow only authorized and responsible personnel to use the equipment.

Download PDF (84 KB)