CT series multifunction batch/counter/timer user manual covering models, technical parameters, operation, batch counting, wiring and connections.
CT series multifunction batch/counter/timer user manual for models CT3, CT4, CT7, CT8 and CT16. It covers model types, technical parameters, panel names, operation flow, batch counting and batch set values, scale coefficient function, mode conversion, counter function mode settings, wiring diagrams, input and output connections, and external dimensions.
The manual includes timing diagrams for multiple action modes and setting menus for counter and timer operation, along with input logic and wiring examples for relay and solid-state outputs. This manual is written in Chinese.
| Power supply | 100-240 V AC/DC |
|---|---|
| Allowable voltage fluctuation | 90-110% of rated voltage (AC power) |
| Input pulse width | Selectable 1 ms or 20 ms |
| External sensor power | 12 VDC ±10%, 100 mA or less |
| Humidity | 35-85% RH |
| Insulation resistance | Minimum 100 MΩ at 500 VDC |
| Withstand voltage | 2000 V AC 50/60 Hz for 1 minute |
| Relay contact capacity | NO: 250 VAC 3 A; NC: 250 VAC 2 A |
| Solid-state output capacity | Maximum 30 VDC, maximum 100 mA |
| Input frequency selection | 1, 30, 1k, 5k, 10 kHz selectable |
| One-shot/control output time | 10/50/100/200/500/1000/2000/5000 ms |
The batch count increases upward and can only be reset to zero by an external batch reset signal; if it exceeds 999999, it automatically resets to zero and starts counting again.
If batch output is ON, it remains ON after power is turned off and on again until an external batch reset signal is received.
In counting mode, batch alarm output occurs when the number of counting alarm outputs equals the batch set value; in timing mode, it occurs when the number of timing alarm outputs equals the batch set value.
NO contacts are rated 250 VAC 3 A and NC contacts are rated 250 VAC 2 A.