CT CT3, CT4, CT7, CT8, CT16 Multifunction Batch/Counter/Timer User Manual

CT series multifunction batch/counter/timer user manual covering models, technical parameters, operation, batch counting, wiring and connections.


CT CT3, CT4, CT7, CT8, CT16 Multifunction Batch/Counter/Timer User Manual - cover page
Brand
C&T
Category
Counter
Document type
User Manual
Language
Chinese
Pages
1
File format
PDF
File size
3.5 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
19FA97809489B6F3AB7FCDEDBCA76FFB

About this manual

CT series multifunction batch/counter/timer user manual for models CT3, CT4, CT7, CT8 and CT16. It covers model types, technical parameters, panel names, operation flow, batch counting and batch set values, scale coefficient function, mode conversion, counter function mode settings, wiring diagrams, input and output connections, and external dimensions.

The manual includes timing diagrams for multiple action modes and setting menus for counter and timer operation, along with input logic and wiring examples for relay and solid-state outputs. This manual is written in Chinese.

What's inside

  • Model description
  • Model types
  • Technical parameters
  • Panel names
  • Operation flow
  • Batch counting and batch set value
  • Scale coefficient function
  • Counter function mode settings
  • Action mode conversion
  • Wiring diagram

Specifications

Power supply100-240 V AC/DC
Allowable voltage fluctuation90-110% of rated voltage (AC power)
Input pulse widthSelectable 1 ms or 20 ms
External sensor power12 VDC ±10%, 100 mA or less
Humidity35-85% RH
Insulation resistanceMinimum 100 MΩ at 500 VDC
Withstand voltage2000 V AC 50/60 Hz for 1 minute
Relay contact capacityNO: 250 VAC 3 A; NC: 250 VAC 2 A
Solid-state output capacityMaximum 30 VDC, maximum 100 mA
Input frequency selection1, 30, 1k, 5k, 10 kHz selectable
One-shot/control output time10/50/100/200/500/1000/2000/5000 ms

Frequently asked questions

How is the batch counter reset?

The batch count increases upward and can only be reset to zero by an external batch reset signal; if it exceeds 999999, it automatically resets to zero and starts counting again.

What happens to batch output after power is turned off and on?

If batch output is ON, it remains ON after power is turned off and on again until an external batch reset signal is received.

When does batch alarm output occur?

In counting mode, batch alarm output occurs when the number of counting alarm outputs equals the batch set value; in timing mode, it occurs when the number of timing alarm outputs equals the batch set value.

What is the relay contact capacity?

NO contacts are rated 250 VAC 3 A and NC contacts are rated 250 VAC 2 A.

Download PDF (3.5 MB)

More C&T Manuals