Operating manual for the Columbia Model 558 knife sterilizer with heating element, covering installation steps, specifications, and safety cautions.
This is the operating manual for the Columbia Model 558, a standard knife sterilizer supplied with a heating element and element guard. The document also references the related Model 555 knife sterilizer, Model 1100 heating element, and Model 549 element guard, and includes dimension drawings for these units.
Step-by-step instructions describe two ways to install the heating element: through a 1" NPT threaded female flange, or through a 1.25" hole using the supplied stainless steel nut and rubber washer. The manual warns that heating elements must be fully submerged at all times and that the box must not be immersed or sprayed because the units are not waterproof. Columbia's contact details in Irvine, California are listed on the specifications page.
| Heating element thread | 1" standard NPT male thread |
|---|---|
| Alternate mounting | 1.25" hole with stainless steel nut and rubber washer |
| Water resistance | Not waterproof; do not immerse or spray the box |
Remove the jam nut and rubber gasket, apply pipe tape to the threads, and screw the heating element into the 1" NPT flange until tight. Fill the box with water before turning the unit on.
Remove the jam nut only, leaving the rubber gasket in place, insert the element through the 1.25" opening, then reinstall and tighten the jam nut securely.
No. Do not immerse or spray the box, as these units are not waterproof.
Heating elements must be fully submerged at all times because a low liquid level will cause burn-out.