Columbia Model 558 Knife Sterilizer with Heating Element Operating Manual

Operating manual for the Columbia Model 558 knife sterilizer with heating element, covering installation steps, specifications, and safety cautions.


Columbia Model 558 Knife Sterilizer with Heating Element Operating Manual - cover page
Brand
Columbia
Category
Sterilizing cabinet
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
675 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
22CAE569DF0708EE525AC64CA1ECE58C

About this manual

This is the operating manual for the Columbia Model 558, a standard knife sterilizer supplied with a heating element and element guard. The document also references the related Model 555 knife sterilizer, Model 1100 heating element, and Model 549 element guard, and includes dimension drawings for these units.

Step-by-step instructions describe two ways to install the heating element: through a 1" NPT threaded female flange, or through a 1.25" hole using the supplied stainless steel nut and rubber washer. The manual warns that heating elements must be fully submerged at all times and that the box must not be immersed or sprayed because the units are not waterproof. Columbia's contact details in Irvine, California are listed on the specifications page.

What's inside

  • Knife Sterilizers
  • Specifications
  • Instructions for Installing Heating Element
  • Installation with 1" NPT threaded female flange
  • Installation with 1.25" hole
  • Caution

Specifications

Heating element thread1" standard NPT male thread
Alternate mounting1.25" hole with stainless steel nut and rubber washer
Water resistanceNot waterproof; do not immerse or spray the box

Frequently asked questions

How do I install the heating element in a knife sterilizer with a 1" NPT threaded female flange?

Remove the jam nut and rubber gasket, apply pipe tape to the threads, and screw the heating element into the 1" NPT flange until tight. Fill the box with water before turning the unit on.

How is the heating element mounted in a sterilizer with a 1.25" hole?

Remove the jam nut only, leaving the rubber gasket in place, insert the element through the 1.25" opening, then reinstall and tighten the jam nut securely.

Can the Columbia Model 558 be immersed or sprayed with water?

No. Do not immerse or spray the box, as these units are not waterproof.

Why must the heating element stay submerged?

Heating elements must be fully submerged at all times because a low liquid level will cause burn-out.