Owner's manual for Columbia davit cranes covering installation, operation, rigging, maintenance, and safety for 500, 1000, and 2000 lb models.
This manual provides installation and operating instructions for Columbia portable davit cranes used for general material handling on a fixed platform. It covers safety precautions, assembly, setup, rigging, operation, service checks, troubleshooting, and warranty information.
The manual addresses 500 lb, 1000 lb, and 2000 lb davit assemblies and optional equipment such as rotation handles, overhaul plates, and limit switches. It also explains capacity changes with boom angle and boom extension and states that the davit is not to be used to lift people or loads over people.
| Load rating | Varies by model; maximum capacity is labeled on the boom and/or name plate |
|---|---|
| Line tension for AALS function | 3% to 5% of the ultimate breaking strength of the line |
| Mounting tolerance | Vertical within ±1° |
| Maximum lifting capacity condition | Boom at maximum elevation and fully retracted |
| Turnbuckle adjustment under load | Not to be adjusted while the system is under load |
No. Columbia products are not to be used to lift people or to lift anything over people.
The AALS function depends on maintaining a line tension of 3% to 5% of the ultimate breaking strength of the line.
No. The turnbuckle is not to be adjusted while the system is under load.
It was designed for material handling on a fixed platform; use on a mobile marine platform is at the user's risk and voids warranties.