This manual provides installation, wiring, and technical specifications for the ColliHigh ZD Series Lux Transmitter.
The ColliHigh ZD Series Lux Transmitter utilizes a high-sensitivity silicon blue photovoltaic detector as its sensor. It is designed with a wide measurement range, ease of use, convenient installation, and long transmission distance. The device supports both current (4mA-20mA) and voltage (0V-5V) output forms. This manual is written in Chinese.
| Supply Voltage | DC 24V (22V~26V) |
|---|---|
| Measurement Range | Lux |
| Output Form (Current) | Two-wire 4mA~20mA |
| Output Form (Voltage) | Three-wire 0V~5V |
| Maximum Allowable Error | ±7% |
| Temperature Characteristic | ±0.5%/℃ |
| Sensing Element | Silicon blue photovoltaic detector with filter |
| Wavelength Measurement Range | 380nm~730nm |
| Operating Environment (with LCD) | 0℃~40℃, 0%RH~70%RH |
| Operating Environment (without LCD) | 0℃~70℃, 0%RH~70%RH |
| Storage Environment (with LCD) | -10℃~50℃, 0%RH~80%RH |
| Storage Environment (without LCD) | -10℃~70℃, 0%RH~80%RH |
| Atmospheric Pressure | 80kPa~110kPa |
| Product Weight | Approx. 170g |
The supply voltage is DC 24V, with a range of 22V to 26V.
The device offers a two-wire current output of 4mA to 20mA or a three-wire voltage output of 0V to 5V.
The maximum allowable error is ±7%.
The wavelength measurement range is from 380nm to 730nm.