Quick reference for installing, connecting, and configuring the Cognex DataMan 475 Verifier, with precautions, accessories, specifications, and regulatory…
The Cognex DataMan 475 Verifier Quick Reference Guide covers installation precautions, product components, accessories, dimensions, and cable connections. It explains how to mount the verifier at the specified distance, connect Ethernet and breakout cables, and configure the device with DataMan Setup Tool.
The guide also provides product specifications and safety and regulatory information. Detailed installation procedures and specifications are referred to the DataMan 475 Verifier Reference Manual installed with the setup software.
| Weight | 945 g |
|---|---|
| Field of view | 80 x 60 mm |
| Dimensions | 185 x 185 x 175 mm |
| Power consumption | 24 VDC ±10%, 1.5 A maximum; Label Light 36 W peak |
| Light connector | 0.4 A; disabled while the Label Light accessory is in place |
| Case temperature | 10 °C to 57 °C (32 °F to 134.6 °F) |
| Operating temperature | 20 °C to 40 °C (32 °F to 104 °F) |
| Storage temperature | -20 °C to 80 °C (-4 °F to 176 °F) |
| Humidity | Less than 95%, non-condensing |
| Ingress protection | IP65 with cables and appropriate lens cover attached |
Mount it so the distance from the bottom of the light housing to the plane of the code is 60 mm, with a stated tolerance of ±3 mm at each corner.
Use a UL or NRTL listed 24 VDC power supply rated for at least 2 A continuous, with a maximum short-circuit current rating below 8 A and maximum power below 100 VA, marked Class 2 or Limited Power Source.
DataMan Setup Tool must be installed on a networked PC. The guide states that the DM475 verifier is not supported in versions earlier than 6.1.7.
See the Connections, Optics, and Lighting section of the DataMan 475 Verifier Reference Manual, which is installed with DataMan Setup Tool.