Installation and operation instructions for CMP multi-port valves (models 27505-200-000 and 27507-200-000), replacements for Pentair filters.
This manual covers the installation, operation, and servicing of CMP RMULTI-PORT VALVE models 27505-200-000 and 27507-200-000. These valves serve as replacements for Pentair model 261055 or 261152, featuring a lever action handle to control six functions: filter, backwash, waste, rinse, closed, and recirculate.
The document provides step-by-step installation instructions, including securing bulkhead nuts by hand only and connecting pump lines according to port markings. It also details service procedures for the valve top half assembly, emphasizing that the top is under spring load and must be loosened evenly. Safety warnings advise turning off the pump before servicing.
The valve has bulkhead fittings with a 7-1/2" centerline distance.
If lubrication is required, only silicone type lubricants should be used.
Screws must be tightened evenly and alternately, and they must not be overtightened.