Featured CMP manuals

CMP RMULTI-PORT VALVE User Manual
This manual covers the installation, operation, and servicing of CMP RMULTI-PORT VALVE models 27505-200-000 and 27507-200-000. These valves serve as replacements for Pentair model 261055 or 261152, featuring a lever action handle to control six functions: filter, backwash, waste, rinse, closed, and recirculate.
The document provides step-by-step installation instructions, including securing bulkhead nuts by hand only and connecting pump lines according to port markings. It also details service procedures for the valve top half assembly, emphasizing that the top is under spring load and must be loosened evenly. Safety warnings advise turning off the pump before servicing.
Covers: Product Information · Valve Setting Water Flow Path · Installation Instructions · Service Instructions · Top Half Assembly Components

CMP 25503-460-XXX 4" LED Bubbler Installation Guide
This guide provides step-by-step instructions for installing the CMP 25503-460-XXX 4" LED bubbler light in swimming pools. It covers safety precautions, plumbing and electrical connections, and maintenance procedures. The light must be installed by a licensed electrician or qualified pool professional using a 12VAC transformer and following NEC or CEC codes. Maintenance includes winterizing steps and replacing components like the L-gasket and LED module.
Covers: Safety Warnings · Included Parts · Vinyl/Fiberglass Installation · Gunite Installation · Plumbing & Electrical Diagrams · Step-by-Step Installation
Latest CMP manuals
CMP RMULTI-PORT VALVE User Manual
User Manual 2 pages · 505 KB · ENInstallation and operation instructions for CMP multi-port valves (models 27505-200-000 and 27507-200-000), replacements for Pentair filters.
CMP 25503-460-XXX 4" LED Bubbler Installation Guide
Installation Guide 16 pages · 3.4 MB · ENInstallation instructions for CMP's 4" LED bubbler light, including safety warnings, plumbing, electrical, and maintenance steps.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in CMP manuals
What is the centerline distance between the valve fittings?
The valve has bulkhead fittings with a 7-1/2" centerline distance.
What type of lubricant should be used on O-rings?
If lubrication is required, only silicone type lubricants should be used.
What voltage does the CMP 4" LED bubbler require?
It requires a 12VAC transformer.
From: CMP 25503-460-XXX 4" LED Bubbler Installation Guide
Who should install this light?
It must be installed by a licensed electrician or qualified pool professional.
From: CMP 25503-460-XXX 4" LED Bubbler Installation Guide