CAREL IR32 Fridge/Freezer Digital Thermostat Parameters

CAREL IR32 digital thermostat parameter sheet for fridge/freezer, covering error codes, set point adjustment, deep programming, reset, and wiring connections.


CAREL IR32 Fridge/Freezer Digital Thermostat Parameters - cover page
Brand
Carel
Category
Refrigerators
Document type
Quick Start Guide
Language
Italian
Pages
2
File format
PDF
File size
63 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2AEAE225595862A6FF3D747350CD3B67

About this manual

This document is the parameter sheet for the CAREL IR32 digital thermostat for fridge/freezer applications. It lists error types and remedies, describes the display and keys, and explains how to modify the set point and deep programming parameters.

Table 1 gives default values and ranges for set point, function mode, differential, output status, and temperature units. Page 2 shows wiring connections for the CAREL IR32V0E000 model, including the NTC probe, 12÷24 Vac/Vdc power supply, and thermostat contact output. This manual is written in Italian.

What's inside

  • Error types and remedies
  • Display and keys
  • Modifying the set point
  • Deep programming
  • Parameter table
  • Reset of the control
  • Wiring connections

Specifications

Power supply12÷24 Vac/Vdc
Default set pointFridge 4°C, Freezer 18°C
Function mode1 (Direct), range 1 ÷ 9
Differential1°C, range 0.1 ÷ 99.9
Temperature unit0 (°C), range 0 (°C) ÷ 1 (°F)
Probe typeNTC

Frequently asked questions

How do I modify the set point?

Press SEL for some seconds until St1 appears, then use Up or Down to set the value and press SEL to confirm.

What is the deep programming password?

The password is 77, selected with the Up key and confirmed with SEL.

How do I reset the control to factory settings?

Switch the instrument off, then switch it back on while holding down the Prg/mute key.

What power supply does the thermostat use?

It uses 12÷24 Vac/Vdc power.