Installation and usage manual for the BSIL E10 multi/single point displacement meter, covering sensor introduction, wiring, assembly, and troubleshooting.
This manual provides instructions for the BSIL E10 multi/single point displacement meter, a device used for measuring displacement in engineering structures. It details the components of the sensor, including the coil section, outer cylinder, sliding rod, and positioning pins, and emphasizes the importance of preventing relative rotation between the outer cylinder and sliding rod to avoid damage.
The document covers the installation process, including the assembly of the measuring rod and protective tube, the composition of the base, and the specific steps for installing the sensor. It also explains the wiring methods for both single-point and multi-point configurations, providing color codes for the 2-core and 4-core cables, and includes a section on fault exclusion. This manual is written in Chinese.
| Drilling Diameter (Single Point with Grouting Anchor) | Minimum 50 mm |
|---|---|
| Drilling Diameter (General) | 75~110 mm |
| Cable Resistance (Steel String Sensor) | 180 ± 10 Ω |
| Cable Resistance (Temperature Sensor at 25°C) | 3k Ω |
| Insulation Resistance | >50M Ω |
It can be used for drilling holes with a minimum diameter of 50 mm.
The positioning pin must enter the slot before rotating the sensor; after removal, they must remain aligned without rotation.
Black and red are for vibration string signal frequency output, while green and white are for the thermistor temperature signal output.