This manual covers the installation, data acquisition, processing, and troubleshooting for the BSIL P6 steel string pressure sensor used in soil mechanics.
The document provides an overview of the BSIL P6 steel string pressure sensor (also known as a total stress meter), explaining its working principle based on Terzaghi's theory and describing its rigid structure suitable for various installations, including compacted concrete. It details dimensions such as a diameter of 230mm and thickness of 11mm. This manual is written in Chinese.
| Diameter | 230mm |
|---|---|
| Thickness | 11 mm |
| Wire Resistance (Red/Black) | 180±10Ω |
| Green/White Wire Resistance | 3000Ω (at 25°C) |
| Insulation Resistance | >20 MΩ |
The difference should not be greater than 50 numbers after temperature, pressure, altitude, and position corrections.
The BSIL-P6 soil pressure meter has a diameter of 230mm and a thickness of 11mm.
After performing temperature, pressure, altitude, and position corrections, the difference between the calibrated zero reading and the actual zero reading should not exceed 50 numbers.
The resistance between the green and white wires should be approximately 3000Ω at 25℃.