Bray FLOW-TEK F15/RF30 two-piece full-port flanged ball valve installation, operation and maintenance manual covering safety, storage, adjustment and assembly.
This manual covers the Bray FLOW-TEK F15/RF30 series two-piece full-port flanged ball valve. It explains the two-piece split body, free-floating ball, part numbering, cutaway views, basic field installation, safety warnings, and short- and long-term storage.
The operating section states that the valve is operated by turning the handle one quarter turn (90 degrees); clockwise closes and counterclockwise opens, with the handle parallel to the pipeline when open and perpendicular when closed. Maintenance content covers stem seal adjustment, ball support packing adjustment, disassembly and cleaning, visual inspection, assembly, and return authorization. This manual is written in Chinese.
| Body design | Two-piece split body |
|---|---|
| Ball design | Free-floating ball |
| Operating turn | 1/4 turn (90 degrees) |
| Body nut torque, 1/2 in F15/F30 | 140 lb-in (16 N·m) |
| Body nut torque, 12 in F15/F30 | 1450 lb-in for F15; 3600 lb-in for F30 (164 N·m; 407 N·m) |
Turn the handle one quarter turn (90 degrees). Clockwise closes the valve and counterclockwise opens it.
Yes. The manual says the valve can be installed in any direction in the pipeline and should be kept fully open during installation.
The handle is parallel to the pipeline when the valve is open.
Before pressurizing the system, the valve must be in the half-open position.