BEA CONDOR / CONDOR XL Motion and Presence Detector for Industrial Automatic Doors User Guide

BEA CONDOR / CONDOR XL motion and presence detector for industrial automatic doors: technical specifications, installation, setup and troubleshooting.


BEA CONDOR / CONDOR XL Motion and Presence Detector for Industrial Automatic Doors User Guide - cover page
Brand
BEA
Category
sensor
Document type
User Manual
Language
Spanish
Pages
8
File format
PDF
File size
479 KB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
13723B9068A2953405E3E826DEA03B30

About this manual

The BEA CONDOR and CONDOR XL are motion and presence detectors for industrial automatic doors. CONDOR is intended for standard mounting at 3.5–6 m, while CONDOR XL is for low mounting at 2–3.5 m. The document gives technical specifications, mounting and wiring information, safety instructions, LED signals, remote-control settings, setup and troubleshooting.

Specifications include 12–24 V AC/DC supply, two potential-free relay outputs, IP65 protection, and a temperature range of -30 to +60 °C, except in cold rooms. The manual also describes radar and active infrared detection, field dimensions, detection modes, filters and factory values. This manual is written in Spanish.

What's inside

  • Especificaciones técnicas
  • Montaje mural y en el techo
  • Instrucciones de seguridad
  • Señales LED
  • Uso del mando a distancia
  • Montaje y cableado
  • Campo radar y ángulo del detector
  • Setup
  • Ajustes con el mando a distancia
  • Funcionamientos incorrectos

Specifications

AC power supply12 V to 24 V AC ±10% (50–60 Hz)
DC power supply12 V to 24 V DC +10% / -3%
Output2 relays with changeover contact, potential-free
Mounting heightCONDOR: 3.5–6 m; CONDOR XL: 2–3.5 m
Operating temperature-30 °C to +60 °C, except cold rooms
Protection indexIP65
Dimensions127 mm (D) x 102 mm (W) x 96 mm (H)
Weight400 g
Radar technologyDoppler radar at 24.150 GHz
Detection typeMotion and presence
Motion detection areaCONDOR: 4 x 5 m; CONDOR XL: 4 x 2 m
Presence detection area4 m x 4 m
Minimum detection speed5 cm/s
Radar angle-8° to +22° relative to front face
Active infrared wavelength875 nm
Cable length10 m

Frequently asked questions

What is the difference between CONDOR and CONDOR XL?

CONDOR is for standard mounting at 3.5–6 m; CONDOR XL is for low mounting at 2–3.5 m.

What AC power supply does the detector accept?

It accepts 12 V to 24 V AC ±10% at 50–60 Hz.

How can the detector be accessed if the access code is unknown?

Cut and reconnect the power supply; for one minute, the detector can be programmed without entering an access code.

What happens after a power cut?

The detector performs a brief setup after each power cut.