User manual for AVSL MSD1 mains-powered inter-connectable smoke detector with 9V battery backup, covering installation, operation, maintenance, and safety.
This user manual provides step-by-step instructions for installing, operating, and maintaining the AVSL MSD1 smoke detector. It includes guidance on proper placement, wiring, testing, and battery replacement. The detector features a photoelectric sensor, inter-connectability with up to 19 other alarms, and a hush feature for temporary silence. Safety precautions and maintenance tips are also detailed.
The manual emphasizes correct installation by a qualified electrician, proper positioning to avoid false alarms, and regular testing to ensure functionality. It also explains the behavior of interconnected alarms and how to handle low battery warnings.
| Power Source | 220-240V ac~ 50-60Hz with 9V battery back-up |
|---|---|
| Battery Back-up | 9V DC Carbon Zinc (Gold Peak 1604 E), 9V Alkaline Battery (Energizer 522) |
| Battery Back-up Life | 1 Month minimum |
| Operation Current | <40mA operation (In Alarm) |
| Sensitivity to smoke | 0.08-0.2db/m |
| Operation Temperature | 0℃-40℃ |
| Ambient Humidity | 10% -90% |
| Alarm Sound Level | 85 Decibels at 3 metres |
| Inter-connect facility | 20 smoke detectors over 150 metres maximum |
| Approved to | BS EN14604 :2005 |
The battery will provide at least one month of operation in case of mains failure.
Press and hold the test button for about 3 seconds to trigger a loud pulsating alarm and a flashing red LED.
Replace the battery immediately, as this indicates the battery is at the end of its life.