The Ascon Tecnologic A30 is a converter between USB, RS-232, RS-485, and TTL interfaces, available in A30U and A30- models. This engineering manual covers outline dimensions, the connection diagram, installation and mounting requirements, preliminary hardware settings, serial interface and power supply details, technical characteristics, and ordering information.

The document also states operating conditions, isolation and EMC compliance details, a 12-month warranty, maintenance guidance, and cleaning instructions.

What's inside

  • Outline Dimensions
  • Connection Diagram
  • Installation
  • Preliminary Hardware Setting
  • Mounting Requirements
  • Serial Interface
  • Power Supply
  • Technical Characteristics
  • Warranty and Repairs
  • How To Order

Specifications

Case material and flammabilityPlastic, self-extinguishing degree V-0 according to UL 94
Terminals protectionIP 20 according to EN 60070-1
Terminal block (power supply)Screw terminals, screw M3, cables 0.25...2.5 mm² (AWG 23 to AWG 14)
Terminal block (RS-232/RS-485)Screw terminals, screw M2, cables 0.25...1.5 mm² (AWG 23 to AWG 16)
Dimensions28 x 88 mm, depth 78 mm
Weight180 g approx.
Power supply (100/240 V option)100...240 VAC (-15...+10%)
Power supply (24 V option)24 VAC/DC (±10%)
Power consumption5 VA max.
Isolation (100/240 VAC supply to communication lines)Reinforced according to EN 61010-1; voltage test 2500 Vrms (1 min)
Isolation (24 VAC/DC supply to communication lines)Reinforced according to EN 61010-1; voltage test 1500 Vrms (1 min)
Isolation (master to slave side)Functional isolation (250 VAC)
Operating temperature0...50°C (32...122°F)
Storage temperature-30...+70°C (-22...+158°F)
Humidity20...85% RH, non condensing
USB compatibility2.0 full speed compliant with USB 1.1
Maximum baud rate (RS-485 only)38400 baud
RS-485 connectionsUp to 30 devices to one remote master unit
Maximum cable length1500 m at 9600 baud
Electromagnetic compatibilityCompliance with directive EMC EN 61326-1 and directive LV EN 61010-1
Installation categoryII
Pollution category2
Warranty period12 months from delivery date

Frequently asked questions

What is the maximum baud rate supported on the RS-485 interface?

38400 baud.

How many RS-485 devices can be connected to one remote master unit?

Up to 30 devices; an isolation unit (RS485 to RS485) is required when other units must be connected.

What is the maximum cable length?

1500 m at 9600 baud.

Is the power supply input fuse protected?

No; provide a T type 1A, 250 V fuse externally.