Installation and use manual for Ariston AR-G22, AR-G50, AR-G80 and AR-G120 multigas gas water heaters, covering connections, gas pressure and safety.
This Spanish installation and use manual covers the Ariston AR-G22, AR-G50, AR-G80 and AR-G120 multigas gas water heaters. It explains warnings, the water heater description, water and gas connections, installation location, wall mounting, gas leak checks, and primary air adjustment.
According to the text, the units use an atmospheric safety pilot and a gas-analyzer pilot that allows conversion between natural gas and packaged gas. The manual gives LPG and natural gas inlet pressures, vent duct diameter, water connection arrangements by model, and details such as the magnesium anode and vitreous enamel tank. This manual is written in Spanish.
| Gas type | Natural gas or packaged gas, with conversion possible |
|---|---|
| LPG inlet pressure | 27.4 hPa (280 mm water column) |
| Natural gas inlet pressure | 17.6 hPa (180 mm water column) |
| Vent duct diameter | 7.6 cm (3 in) |
| Reversible water connection | Available on AR-G22 and AR-G50 |
| AR-G80 and AR-G120 water connection | Top of tank only |
| Tank coating | Vitreous enamel coating |
| Anode | Anti-corrosion magnesium anode |
| Ignition | Piezoelectric burner ignition |
| Thermostat | Automatic thermostat maintains constant water temperature |
| Safety pilot | Stops gas flow if the flame goes out |
Use soapy water on all gas and water connections; bubbles indicate a leak. Never use a flame to check for leaks.
The LPG inlet pressure should be set to 27.4 hPa, or 280 mm water column.
No. Their water connection is only at the top of the tank.
Loosen the screw that fixes the primary air adjuster and open the primary air until the flame is blue and stable. Avoid opening it too far, which can lift the flame off the burner.