This guide details configuring RoCE, PFC, and ECN on Arista switches and Broadcom NICs for high-performance AI/ML and HPC networks.
This deployment guide explains how to set up a lossless network using Remote Direct Memory Access (RDMA) over Converged Ethernet (RoCE) for AI/ML, storage, and High-Performance Computing (HPC) applications. It focuses on eliminating connectivity bottlenecks by leveraging Broadcom Ethernet Adapters and Arista Networks switches based on Broadcom's DNX and XGS family of ASICs.
The document provides specific instructions for configuring Priority Flow Control (PFC) and Explicit Congestion Notification (ECN) on Arista switches, including the 7800R, 7280R, 7060X, and 7050X series. It also covers the installation and configuration of RoCE drivers and libraries on Broadcom Ethernet NIC adapters, along with performance testing methods.
| Supported Switch Series | 7800R series, 7280R series, 7050X series, 7060X series |
|---|---|
| Chipset Families | Broadcom DNX and XGS family of ASICs |
| PFC Watchdog Timeout | 1.0 second |
| PFC Watchdog Recovery-time | 2.0 second |
| PFC Watchdog Polling-interval | 0.2 second |
Arista EOS supports RoCE deployments across the 7280R series, 7800R series, 7050X series, and 7060X series.
The PFC watchdog monitors the system and takes action, such as dropping traffic, if the watchdog timeout is exceeded.
ECN is configured at the egress Tx-Queue of an Interface using the random-detect ecn command.