APG VBL Series General Purpose Vibrating Level Sensor Operator's Manual

Operator's manual for the APG VBL Series general purpose vibrating level sensor for solid level measurement.


APG VBL Series General Purpose Vibrating Level Sensor Operator's Manual - cover page
Brand
APG
Category
sensor
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
373 KB
Published
14 November, 2026
Updated
14 November, 2026
MD5 checksum
2283F8F60C66BEA2FE9129EB4EC426A9

About this manual

APG VBL Series general purpose vibrating level sensors are made for solid level measurement in containers. The VBL-12, VBL-22, and VBL-32 versions cover compact, extended probe, and flexible extension installations, and the sensor is designed for a minimum bulk density of 12 lbs per cubic foot (0.2 g/cm3). It can be used with fine powders, ordinary powders, granular materials, pellets, and sediments in liquids such as sludge or sand.

The manual covers specifications, dimensions, nomenclature, electronics, principle of operation, installation, adjustment, sensitivity, wiring, start up, maintenance, and troubleshooting. Documented specifications include a 1 SPDT output rated 240 V 3 A AC or 30 V 3 A DC, vibration frequency of approximately 330 Hz, supply voltage of 90 to 132 VAC, 180 to 264 VAC, or 24 VDC, and an IP65/NEMA 4 enclosure.

What's inside

  • Introduction
  • Specifications
  • Dimensions
  • Nomenclature
  • Electronics
  • Principle of Operation
  • Installation
  • Adjustment Procedure
  • Wiring
  • Troubleshooting

Specifications

Minimum bulk density12 lbs/ft3 (0.2 g/cm3)
Operational versionsVBL-12 compact; VBL-22 extended probes; VBL-32 flexible extension
Output contact rating1 SPDT, 240 V 3 A AC, 30 V 3 A DC (resistive)
Vibration frequencyApproximately 330 Hz
Sensitivity adjustmentsVery High, High, Standard, Low
Loss of power modeProvided (high or low) by switch
Detection time delayCovered 1 sec; free 5 sec
IndicationGreen LED power status; red LED relay status
Supply voltage90 to 132 VAC, 180 to 264 VAC, or 24 VDC
Power consumptionApproximately 5 VA
Housing materialAluminum die cast (ADC)
Vibration probe material304SS (316SS optional)
Cable entriesG 3/4, G 1/2, or NPT 1/2
Enclosure ratingIP65/NEMA 4
Operating temperatureVBL-12/22 vibration rod -4 to 300°F (-20 to 150°C), housing -4 to 140°F (-20 to 60°C); VBL-31 vibration rod -4 to 158°F (-20 to 70°C), housing -4 to 140°F (-20 to 60°C)
Maximum pressure290 psi (20 bar)

Frequently asked questions

What is the minimum bulk density the VBL sensor can detect?

The sensor is designed for a minimum bulk density of 12 lbs per cubic foot (0.2 g/cm3).

What output contact rating does the VBL sensor provide?

It provides one SPDT contact rated 240 V 3 A AC and 30 V 3 A DC (resistive).

What supply voltages can be used with the VBL sensor?

The supply voltage can be 90 to 132 VAC, 180 to 264 VAC, or 24 VDC.

What is the vibration frequency of the VBL sensor?

The vibration frequency is approximately 330 Hz.