Service manual with safety rules, identification, specs, tools, maintenance schedule and detailed repair steps for Annovi Reverberi 194 and 366 series water…
The manual covers safety precautions, product identification, technical specifications, required tools, and a maintenance schedule for Annovi Reverberi water pumps.
It provides step‑by‑step repair procedures for the 194 and 366 series, warranty information, and a troubleshooting guide for common issues. This manual is written in Chinese.
| Oil change interval | First change after 50 h, then every 500 h |
|---|---|
| Minimum pneumatic wrench torque | 60 Nm |
| Recommended oil grade | SAE 10W-30 |
| Standard pump speed | 1450 RPM |
Replace the oil after the first 50 hours of operation, then every 500 hours thereafter.
The pneumatic wrench must be set to at least 60 Nm.
All pipe pressure must be released before any maintenance work.