This application note explains how to use the RS-232 port on Allied Vision GigE cameras for serial communication, including wiring diagrams, terminal setup…
This document provides instructions for using the RS-232 port on Allied Vision GigE cameras to send and receive serial commands. It details the physical connection requirements, including specific wiring configurations for different camera models like Manta, Prosilica GB, and Prosilica GT series, connecting the Hirose connector to a 9-pin DSUB connector.
| Baud Rate (Manta and GT) | 115200 |
|---|---|
| Baud Rate (Default) | 9600 |
| Data Bits | 8 |
| Stop Bits | 1 |
| Parity | None |
| Flow Control | None |
The default settings are Baud Rate 9600, 8 Data Bits, 1 Stop Bit, No Parity, and No Flow Control.
The Manta and GT series models use a baud rate of 115200.
Open SampleViewer, click the 'IIOI' icon, set parameters to match terminal settings, click 'Connect', and type text to verify transmission.