Installation and operation instructions for the Allegion 18782 Sentronic concealed door closer, including wiring, mounting, and regulation steps.
This document provides installation instructions for the Allegion 18782 Sentronic concealed door closer. It details the assembly of the track and conduit, mounting the closer to the door, and connecting the electrical components. The guide specifies that the closer must match the hand of the door and that the voltage on the cover plate must match the supplied voltage.
| Input Voltage | 12V AC/DC, 24V AC/DC, or 115V AC/DC |
|---|---|
| Hold Open Range | 85° to 110° |
| Nominal Voltage (Hold Open) | 12 VAC - DC Nominal + 10% - 15% |
| Max Current (Hold Open) | .180 Amp. Max. |
| Nominal Voltage (Release) | 24 VAC - DC Nominal + 10% - 15% |
| Nominal Voltage (Release) | 120 VAC - DC Nominal + 10% - 15% |
A normal closing time from a 90° open position is 5 to 7 seconds, evenly divided between main swing speed and latch swing speed.
To slow the MAIN SPEED of the door, turn the regulating screw nearest the arm clockwise.
The minimum door width is 2' 6" (2 feet 6 inches).