The AlarmKing SR800E manual explains features, installation, operation, and maintenance of the wireless intelligent alarm system.
This manual introduces the AlarmKing SR800E wireless intelligent alarm system, detailing its smart micro‑computer control, anti‑theft, gas leak, smoke detection, emergency call, and remote monitoring functions. It also describes the system’s components, including the main unit, remote controller, infrared detector, door sensor, and backup power.
Installation instructions cover mounting of infrared detectors and door sensors, wiring diagrams, and configuration of up to four alarm zones. Operational guidance includes arming/disarming, emergency alarm activation, remote programming, phone‑line monitoring, and routine maintenance to ensure reliable performance. This manual is written in Chinese.
| Power Supply | DC9‑12V |
|---|---|
| Backup Runtime (Power Outage) | >48 hours |
| Number of Alarm Zones | 4 |
| Phone Groups for Alarm Calls | 6 |
| Battery Life (Remote, Detector, Door Sensor) | 6‑12 months |
Press the remote’s “设防” (arm) key followed by “9” to arm, and press the “撤防” (disarm) key followed by “0” to disarm.
Press the remote’s “紧急” key for an audible alarm, or press the “静音” key for a silent alarm that calls without sounding the siren.
The system supports up to four independent alarm zones.
The backup power can operate the system for more than 48 hours without external power.