Airnergy+ Basis Plus Inhalation Device User Manual

User manual for the Airnergy+ Basis Plus device covering intended use, setup, operation, service functions, maintenance, and technical data.


Airnergy+ Basis Plus Inhalation Device User Manual - cover page
Brand
AIRNERGY
Category
Health Care
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
2.8 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2165330164EBF2381DB9A9315E0B2447

About this manual

The Airnergy+ Basis Plus User Manual covers important information, directions for use, starting up the device, operating the control panel, service functions, care of the device, Service-Check 2000, technical data, accessories, and ISO certificates. It lists safety standards including IEC 60601-1 series and states that the device is operated with the supplied FW7362M/12 mains adaptor at 12 V DC.

The manual describes inhalation of physical conditioned ambient air through nasal cannulas to improve the regulation ability of the autonomic nervous system. It includes a recommended application time of 40 minutes at 100% intensity, selectable intensity levels of 50%, 75%, and 100%, air filter replacement every 50 hours, and automatic shutdown after 15 minutes without operation.

What's inside

  • Important information
  • Directions for use
  • Starting up the device
  • Manual of the device
  • Service functions
  • Looking after the device
  • Service-Check 2000
  • Technical data: Device
  • Technical data: Power supply
  • Accessories

Specifications

Mains adaptorFW7362M/12 from FRIWO Gerätebau GmbH
Device input12 V DC
Maximum ambient temperature40°C
Maximum atmospheric humidity90 %
Air filter replacement intervalEvery 50 hours
Intensity levels50%, 75%, and 100%
Recommended application time40 minutes at 100% intensity
Automatic shut downAfter 15 minutes without operation
WarrantyTwo years from the date of invoice
Water fill for glass bottleApprox. 250 ml, max. half-full

Frequently asked questions

What is the Airnergy+ Basis Plus used for?

The manual states it is for inhalation of physical conditioned ambient air through nasal cannulas to improve the regulation ability of the autonomic nervous system.

How often must the air filter be replaced?

It should be replaced every 50 hours; at 50 hours the display shows a “Change filter” message.

What intensity levels can be selected?

In Operational Mode 1, the INTENSITY button selects 50%, 75%, or 100% intensity.

What happens when the application time ends or is stopped?

A brief acoustic signal sounds; after a short run-on the device is operational again and the application can be resumed with START.