Afag KLF5 KLF7 KLF15 KLF25 Linear Feeder Operating & Installation Instructions

Operating and installation instructions for Afag KLF5, KLF7, KLF15 and KLF25 linear feeders in 230 V/50 Hz and 115 V/60 Hz versions.


Afag KLF5 KLF7 KLF15 KLF25 Linear Feeder Operating & Installation Instructions - cover page
Brand
AFAG
Category
Automation control Equipment
Document type
User Manual
Language
English
Pages
44
File format
PDF
File size
2.4 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
27116D137565FEB4B1A2635069783626

About this manual

This document is the English translation of the original operating and installation instructions (version 7.0, dated 24.08.2023) for the Afag linear feeders KLF5, KLF7, KLF15 and KLF25. It covers the complete and basic-unit order numbers for each model in both the 230 V/50 Hz and 115 V/60 Hz versions, and it explains the intended use of the feeders: transporting, buffering and arranging parts.

The manual guides the reader through safety instructions and residual risks, technical data and dimensional drawings, transport, packaging and storage, the structure and description of the KLF, and installation, assembly and setting, including conveyor rail assembly, electrical connection, balance of weights, natural frequency fine adjustment and air gap adjustment. Further chapters cover commissioning, fault elimination, maintenance and repair with leaf spring checks and spare/wear parts lists, and decommissioning and disposal.

What's inside

  • General – contents and purpose of the manual, symbols, warranty, liability
  • Safety instructions – intended use, misuse, obligations and personnel requirements
  • Technical data – dimensional drawings and technical data for KLF5 and KLF7–KLF25
  • Accessories – mounting parts and controller
  • Transport, packaging and storage
  • Design and description of the KLF
  • Installation, assembly and setting – conveyor rails, electrical connection, settings
  • Operation – commissioning of the modules
  • Fault elimination – fault causes and remedy
  • Maintenance and repair – maintenance intervals, leaf springs, spare and wear parts

Specifications

Available modelsKLF5, KLF7, KLF15, KLF25
Supply voltage variants230 V/50 Hz and 115 V/60 Hz
Intended useTransporting, buffering and arranging parts
Permissible ambient temperature10 °C to 45 °C (use below 10 °C or above 45 °C is improper)
Warranty period24 months from initial operation, maximum 27 months from delivery

Frequently asked questions

What is the Afag KLF linear feeder used for?

According to the intended use section, the linear feeder may only be used for transporting, buffering and arranging parts.

Which voltage and frequency versions are listed?

The instructions list each model in a 230 V/50 Hz version and a 115 V/60 Hz version, as complete unit or basic unit with separate order numbers.

What are the warranty terms for Afag handling components?

The warranty is 24 months from initial operation and up to a maximum of 27 months from delivery; wear parts are excluded.

Where must the linear feeder not be used?

Improper uses include damp and wet areas, temperatures below 10 °C or above 45 °C, and areas with highly flammable, explosive or aggressive media.

Download PDF (2.4 MB)

More AFAG Manuals


View all AFAG manuals →