Operating instructions for the ABB TZIDC-200 electro-pneumatic positioner designed for 4...20 mA two-wire technology with a flameproof enclosure.
This document provides operating instructions for the ABB TZIDC-200 Electro-Pneumatic Positioner, which is designed for 4...20 mA two-wire technology and features a flameproof enclosure. The manual covers safety summaries, manufacturer information, installation procedures (mechanical mounting, pneumatic and electrical connections), commissioning steps, functional tests, maintenance guidelines, and technical data.
The device is designed for 4...20 mA two-wire technology.
The maximum admissible operating pressure is 6 bar (90 psi).
The safety shutdown module must be subject to a functional test every two years at the latest.