ABB ACS880-31 Industrial Drive Quick Installation and Startup Guide

This guide provides instructions for the installation, wiring, and startup of the ABB ACS880-31 industrial drive.


ABB ACS880-31 Industrial Drive Quick Installation and Startup Guide - cover page
Brand
ABB
Category
Industrial Robot
Document type
Installation Guide
Language
Chinese
Pages
16
File format
PDF
File size
10.8 MB
Published
18 October, 2026
Updated
18 October, 2026
MD5 checksum
C1A3C086CFC5A30D925C2E54571D1812

About this manual

This document serves as a quick installation and startup guide for the ABB Industrial Drive ACS880-31. It outlines essential safety precautions, site inspection requirements, and specific steps for mounting the drive on a wall. The guide covers necessary checks for the installation environment, including ventilation and material flammability, to ensure safe operation. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Site Inspection
  • Wall Mounting
  • Grounding System
  • Insulation Resistance Measurement
  • Power Cable Connection
  • Motor Cable Connection
  • Torque Specifications

Specifications

Mounting Torque (R3)1.7 N·m

Frequently asked questions

How long must one wait after disconnecting the input power before working on the drive?

You must wait 5 minutes to allow the intermediate circuit capacitors to discharge.

What voltage is required to measure the insulation resistance of ABB motors?

You must use a measurement voltage of 1000 VDC.

What is the minimum required insulation resistance for ABB motors at 25°C?

The insulation resistance must exceed 100 Mohm.