SEA HED4 pressure relay pressure to 35MPa Manual

HED4 type pressure relay is a plunger pressure relay, which can be used for bottom plate installation, pipe installation and as a vertical overlay in horizontal combination assembly valve, working pressure range is 5~35MPa.


SEA HED4 pressure relay pressure to 35MPa Manual - cover page
Brand
SEA
Document type
Installation Guide
Language
Chinese
Pages
4
File format
PDF
File size
559 KB
Updated
30 September, 2023
MD5 checksum
232919CBA03FFDA4801649B489104049

About this manual

This manual describes the HED4 hydraulic pressure relay, its construction, and how it detects pressure to control circuit contacts. It includes technical data such as pressure ranges, switching accuracy, and electrical ratings.

The document covers three mounting methods—bottom‑plate installation, pipe installation, and use as a vertical stacking component in horizontal assembly valves—along with wiring diagrams, component dimensions, and part numbers needed for proper installation. This manual is written in Chinese.

What's inside

  • Technical Data
  • Component Dimensions
  • Installation Options
  • Circuit Connection
  • Relay Construction
  • Specifications

Specifications

Maximum set pressure35 MPa
Switching accuracy±1 % of set pressure
Switching frequency120 /min
AC contact load250 V 5 A
DC contact load50 V 1 A
IP ratingIP65
Weight (relay)0.6 kg
Compatible hydraulic oilMineral oil (DIN 51524/51525) and phosphate oil

Frequently asked questions

What is the maximum pressure setting for the HED4 pressure relay?

The HED4 can be set up to a maximum pressure of 35 MPa.

What mounting methods are supported by the HED4 pressure relay?

It can be installed on a bottom plate, in a pipe, or used as a vertical stacking component in a horizontal assembly valve.

What is the switching accuracy of the HED4 relay?

The switching accuracy is within ±1 % of the set pressure.

Download PDF (559 KB)

More SEA Manuals


View all SEA manuals →