The 902 HVAC Clamp Meter is a handheld, battery-powered, multi-function meter that measures AC current, DC current (up to 200 µA with flame detection probe), AC and DC voltage, capacitance, resistance, continuity, and temperature.
This manual introduces the Fluke 902 HVAC Clamp Meter, a handheld device for measuring AC/DC voltage, current, resistance, continuity, temperature, capacitance, and micro‑ampere levels. It lists the included accessories, safety warnings, and contact information for Fluke support.
The guide details how to use each measurement function, explains the display features such as MIN‑MAX recording and auto‑shutoff, and covers maintenance procedures like cleaning and battery replacement. Technical specifications, environmental limits, and certification data are provided at the end of the document. This manual is written in Chinese.
| DC Voltage Range | 0 – 600 V |
|---|---|
| AC Voltage Range (RMS) | 0 – 600 V |
| AC Current Range (RMS) | 0 – 600 A |
| DC Current Range | 0 – 200 µA |
| Resistance Range | 0 – 999 Ω |
| Temperature Range | -10 to 400 °C |
| Capacitance Range | 1 – 100 µF |
| Physical Size (H×W×L) | 9.1 × 3.8 × 1.7 in (240 × 80 × 40 mm) |
| Weight | 1.1 lb (310 g) |
| IP Rating | IP30 |
The product is covered by a three‑year limited warranty for materials and workmanship.
It uses two AA alkaline batteries, which are installed in the device.
The meter has an IP30 rating.
It can operate from –10 °C to +50 °C.