The IBM® Tivoli® Netcool/OMNIbus Heartbeat Probe 5.0 Reference Guide describes the features and characteristics of the product.
This guide describes the IBM Tivoli Netcool/OMNIbus Heartbeat Probe 5.0, a stand-alone probe that generates standard events at predetermined intervals instead of collecting data from a third-party system. It can be used to check that a remote site can be accessed and to generate test events.
The guide covers probe installation, data acquisition behavior, peer-to-peer failover with master and slave probes, example property file settings, probe-specific properties and command line options, and the elements generated for the ObjectServer.
| Patch number | 5.0 |
|---|---|
| Probe executable name | nco_p_heartbeat |
| Properties file | $OMNIHOME/probes/arch/heartbeat.props |
| Rules file | $OMNIHOME/probes/arch/heartbeat.rules |
| Connection method | SIGALRM |
| Remote connectivity | No |
| Multicultural support | Available |
| Peer-to-peer failover functionality | Available |
| IP environment | IPv4 and IPv6 |
| NumEvents default | -1 (unlimited number of events) |
| SleepTime default | 60 seconds |
| Multiplier default | 1 |
It does not gather data from any third party system, but generates a standard event at a predetermined interval, for a predetermined amount of time. It is used to check that a remote site can be accessed and as a test probe when events are required to be generated.
The probe generates an event every SleepTime seconds and repeats this for NumEvents times, or until stopped. The default SleepTime is 60 seconds.
Two probes run simultaneously, with one acting as master and sending events to the ObjectServer while the other acts as slave on standby. If the master fails, the slave activates and forwards events on behalf of the master.
The probe supports IPv4 and IPv6. IPv6 support applies when running on IBM Tivoli Netcool/OMNIbus V7.3.0, 7.3.1 and 7.4.0 on all UNIX and Linux operating systems.