Andreas Hettich GmbH & Co. KG AB1800ZH EBA 200 EBA 200 S ZH Operating Instructions

The AB1800ZH is a high-end centrifuge that is widely used in testing and centrifugation processes that comply with different versions of standards and regulations.


Andreas Hettich GmbH & Co. KG AB1800ZH EBA 200 EBA 200 S ZH Operating Instructions - cover page
Brand
Hettich
Category
Professional medical equipment
Document type
User Manual
Language
Chinese
Pages
42
File format
PDF
File size
1.7 MB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
E42B17790A1F0FC63B3FAE46ADEEDA09

About this manual

This is the Chinese-language operating instructions (document AB1800ZH, Rev. 08 / 12.2022) for the Hettich EBA 200 and EBA 200 S laboratory centrifuges, published by Andreas Hettich GmbH & Co. KG in Tuttlingen, Germany. It states that the centrifuges are in vitro diagnostic medical devices used to centrifuge and refine human sample material for further processing, and that they may only be used by trained personnel in a closed laboratory.

The manual covers the standards and regulations the device is designed to, safety notes, transport and storage, scope of delivery, start-up, opening and closing the lid, loading the rotor, operating and display elements, entering centrifugation parameters (RPM, RCF, radius, run time), centrifugation runs, the cycle counter, settings and queries, emergency release, cleaning and disinfection, autoclaving, malfunctions, replacing the power input fuse, return and disposal, and accessories. Technical data are given for both models, including speeds of 6000 RPM (EBA 200) and 8000 RPM (EBA 200 S), a maximum capacity of 8 x 15 ml, and dimensions of 261 x 353 x 228 mm. This manual is written in Chinese.

What's inside

  • Intended use
  • Safety notes
  • Technical data
  • Loading and unloading the rotor
  • Operating and display elements
  • Entering centrifugation parameters
  • Centrifuge operation
  • Maintenance and care
  • Malfunctions
  • Replacing the power input fuse

Specifications

Maximum capacity8 x 15 ml
Speed (EBA 200 / EBA 200 S)6000 RPM / 8000 RPM
Acceleration RCF (EBA 200 / EBA 200 S)3461 / 6153
Permitted density1.2 kg/dm3
Rated supply voltage200 - 240 V 1~ or 100 - 127 V 1~
Rated frequency50 - 60 Hz
Connection value100 VA (EBA 200) / 160 VA (EBA 200 S)
Dimensions (W x D x H)261 mm x 353 mm x 228 mm
Weightapprox. 9 kg (EBA 200) / approx. 11 kg (EBA 200 S)
Noise level≤ 50 dB(A) / ≤ 55 dB(A), depending on the rotor
Ambient temperature2°C to 40°C
Degree of protectionProtection class I

Frequently asked questions

What are the EBA 200 and EBA 200 S used for?

They are in vitro diagnostic medical devices used to centrifuge and refine human sample material for further processing to meet diagnostic needs, and may only be used by trained personnel in a closed laboratory.

What speed and RCF do the two models reach?

The EBA 200 reaches 6000 RPM and an RCF of 3461; the EBA 200 S reaches 8000 RPM and an RCF of 6153.

Which fuse does the EBA 200 (model 1800) use?

The EBA 200 model 1800 uses a T 1,6 AH/250V fuse with order number E891.

Can the centrifuge be used in explosive atmospheres?

No. The device is not suitable for use in areas with an explosion hazard.