This document describes the features and specifications of the PMK 8 Pre-Mount Kit, PMK 6 Pre-Mount Kit, and PMK 3 Pre-Mount Kit.
This Chinese-language quick start guide covers four Tannoy installation accessories: the Back Can S, an optional steel back can for PCI and QCI in-ceiling loudspeakers, and the PMK 8, PMK 6 and PMK 3 pre-mount kits for PCI and QCI 8", 6" and QCI 3" in-ceiling loudspeakers. Each accessory is supplied separately, and this guide covers all of them.
The guide opens with safety notices and warranty/legal information, then describes unpacking and checking for shipping damage, and identification of the PMK kit and back can features. Installation steps cover mounting the back can between ceiling joists and wiring it through the cable gland, attaching the optional PMK kit to the back can or directly to joists, installing drywall and cutting the ceiling opening with or without a PMK kit, followed by a dimension drawing. This manual is written in Chinese.
| Ceiling type for back can installation example | Typical 2" x 6" ceiling with 16" centers |
|---|---|
| Back can fastening | 5 screws or nails per stud |
| Drywall screw spacing | Approximately 8 to 10 inches apart |
| PMK kit contents | Two mounting brackets, one circular frame and four small clips |
The PMK 8 is for PCI and QCI 8" in-ceiling loudspeakers, the PMK 6 for PCI and QCI 6" in-ceiling loudspeakers and the PMK 3 for QCI 3" in-ceiling loudspeakers.
Yes. The guide states the PMK 6 and PMK 8 kits can be used with or without the Back Can S, and the Back Can S can be used with or without a PMK 6 or PMK 8 kit.
No, the guide states that the back can is not used with the PMK 3.
The guide warns that the procedure requires personal protective equipment such as safety glasses and gloves.