UT803 Digital Bench-Type True RMS Multimeter Operation Manual

This document is about the operation manual of the UT803 multimeter, which introduces the usage and precautions of the multimeter.


UT803 Digital Bench-Type True RMS Multimeter Operation Manual - cover page
Category
Other Electronics
Document type
User Manual
Language
English
Pages
56
File format
PDF
File size
2.6 MB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
B1B30C4D31D67D4AAC2BFE469E991B59

About this manual

The UT803 is a digital bench-type true RMS multimeter with autorange and manual range options and a maximum reading of 5999. It provides DC/AC voltage and current, resistance, diode, continuity, capacitance, temperature, transistor, max/min, data hold, and display backlight functions.

The manual covers safety information, operating rules, meter structure, rotary switch positions, measurement procedures, hold and button functions, general and accuracy specifications, maintenance, and RS232C/USB serial port connection and settings.

What's inside

  • Overview
  • Safety Information
  • Rules For Safe Operation
  • Rotary Switch
  • Measurement Operation
  • Operation of Hold Mode
  • General Specifications
  • Accuracy Specifications
  • Maintenance
  • RS232C and USB Serial Port

Specifications

Maximum display5999
Measurement speed2-3 updates/second
Range selectionManual or auto ranging
Operating temperature0°C to +40°C
Storage temperature-10°C to +50°C
Relative humidity75% at 0-30°C; 50% at 30-40°C
AltitudeOperating 2000 m; storage 10000 m
PowerAC 200-240 V, 50 Hz or six 1.5 V R14 batteries
Dimensions (H x W x L)105 x 240 x 310 mm
WeightApprox. 2 kg (accessories excluded)
Safety/complianceIEC61010 CAT. I 1000 V, CAT. II 600 V overvoltage and double insulation
Fuse protection (10 A terminal)10 A, 1000 V, fast type, φ10.3×38 mm
Accuracy guarantee1 year
Accuracy operating temperature23°C ±5°C
Accuracy relative humidityNot more than 75% RH
Temperature coefficient0.1 × specified accuracy / 10°C
Input impedance (600 mV range)Around >3000 MΩ
Input impedance (other ranges)Around 10 MΩ
DC voltage ranges600 mV, 6 V, 60 V, 600 V, 1000 V
DC voltage resolution0.1 mV to 1 V
DC voltage accuracy(0.6%+2), (0.3%+2), (0.5%+3)
RS232C default baud rate19200

Frequently asked questions

What is the maximum reading on the UT803 display?

The maximum digital display reading is 5999.

What power options does the UT803 support?

It can be powered by AC 200-240 V at 50 Hz or by six 1.5 V R14 batteries.

What safety standard does the meter meet?

It complies with IEC61010 CAT. I 1000 V, CAT. II 600 V overvoltage and double insulation.

What is the default RS232C baud rate?

The default RS232C serial port baud rate is 19200.

Download PDF (2.6 MB)