EK-XRES 100/140 Revo D5 Series Reservoir Installation and Mounting Manual
This document is the installation and mounting manual for the EK-XRES 100/140 Revo D5 Series reservoir from EK Water Blocks, released on 28 August 2015. It is intended for installation only by expert users, and EK Water Blocks states that improper installation may result in damage to equipment.
The manual walks through preparing the Laing D5 pump, installing the EK-XRES Revo D5 onto the pump motor housing with the enclosed 61x3mm o-ring gasket and M74 nut, optionally replacing the default Anticyclone with polyether anti-vortex foam or an EK-HD Tube, mounting the unit to the computer chassis with the EK-Revo D5 Holder, and attaching fittings to the G1/4 inlet and outlet ports. It closes with leak-testing advice, disclosures and a 24-month warranty statement.
| Threaded ports | 3 G1/4 ports (1 inlet, 1 outlet) |
|---|---|
| Sealing gasket | 61x3mm o-ring gasket |
| Pump nut | M74 Nut |
| Holder screws | 4x M4x10 DIN7984 screws with PVC washers |
| Max fitting thread length | 5mm |
| Warranty period | 24 months |
You can rotate the pump and use it in any direction except upside-down.
When the reservoir sits upright, the outlet (pressure) port is positioned lower than the inlet port.
Yes, EK recommends a 24 hour leak test prior to powering up the computer, and warns not to test with tap water pressure.
The product is warranted against defects in materials or workmanship for 24 months from delivery to the final user.