F4 connector product manual, introduces the features and installation instructions of F4 connector.
This manual covers the Tengfang Zhongke F4 connector system, including receiver frame CMV02185 and ITA frame CMV02285. It describes component identification, receiver-to-ITA connection, panel mounting, rear-shell and module service, cable clamps, protective covers, anti-misinsertion components, and troubleshooting.
Procedures include mounting the receiver frame with UNC 4-40 hardware, tightening modules to 0.2 Nm, calculating cable bundle diameter, and using up to 36 anti-misinsertion combinations. This manual is written in Chinese.
| Receiver frame model | CMV02185 |
|---|---|
| ITA frame model | CMV02285 |
| Receiver protective cover model | CMV02185-02 |
| ITA protective cover model | CMV02285-04 |
| Anti-misinsertion component model | CMV02803 |
| Maximum cable bundle diameter (90-degree exit) | 31.5 mm |
| Maximum cable bundle diameter (clamp formula) | 27.15 mm |
| Module fastening torque | 0.2 Nm |
| Anti-misinsertion pin fastening torque | 0.25 Nm |
| Anti-misinsertion combinations | 36 |
| Panel mounting screw | UNC 4-40 |
| Accepted anti-misinsertion sets | 2 |
Align the locating pins, push the ITA to the receiver with about 5 mm remaining gap, then turn the handle clockwise 180 degrees.
Tighten the module screws alternately to 0.2 Nm.
The design accepts two sets of components, for 36 combinations.
Remove the handle screw, pull out the handle, remove the four countersunk screws, then lift the rear shell.