BEKA BA354D and BA358C Intrinsically Safe 4/20mA Loop Powered Rate Totalisers Application Guide

The BA354D and BA358C are intrinsically safe 4/20mA loop powered rate totalisers. They are ATEX certified instruments which bring the simplicity and reliability of BEKA loop powered indicators to flow measurement. Requiring no additional power supply, they may be connected in series with the output of any 4/20mA flow transmitter to provide an accurate local display of the flow rate and total flow.


BEKA BA354D and BA358C Intrinsically Safe 4/20mA Loop Powered Rate Totalisers Application Guide - cover page
Brand
BEKA
Category
Other Electronics
Document type
Installation Guide
Language
English
Pages
5
File format
PDF
File size
606 KB
Published
24 November, 2023
Updated
24 November, 2023
MD5 checksum
DE10AE9E9532158135F0A2577F9EEEC3

About this manual

The BEKA BA354D and BA358C are intrinsically safe 4/20mA loop powered rate totalisers that display flow rate and total flow without needing an additional power supply. They connect in series with any 4/20mA flow transmitter and are ATEX certified for installation in all zones and gas groups.

The BA354D uses a rugged IP66 GRP enclosure for field mounting, while the BA358C uses a 144 x 72mm DIN panel mounting enclosure. Both models introduce less than a 1.1V drop in the loop and store total and programme parameters in permanent memory if input current falls below approximately 3mA.

What's inside

  • Introduction
  • Description
  • Intrinsic Safety Certification
  • European certification
  • 4/20mA input
  • Reset terminals RS1 and RS2
  • Zones, gas groups and T rating
  • Optional alarms

Specifications

Loop voltage dropless than 1.1V
Input current low thresholdapproximately 3mA
ATEX certificationGroup II, Category 1G EEx ia IIC T5
Ambient temperature-40 to 60°C
BA354D enclosureIP66 GRP
BA358C enclosure144 x 72mm DIN panel mounting

Frequently asked questions

Can the BA354D and BA358C be installed in Zone 0?

Yes, they are certified for installation in all zones including Zone 0.

What happens if the input current falls below 3mA?

The total display and programme parameters are stored in permanent memory and recovered when current is restored.

Do the instruments require an additional power supply?

No, they are loop powered and require no additional power supply.