DeFelsko PosiTest AIR Leak Tester Instruction Manual

The PosiTest AIR is a portable, hand-operated air leak tester that tests the air barrier integrity of single, two-ply and liquid membrane systems, including air barriers, roofing systems, waterproofing and ground liners, by locating leaks.


DeFelsko PosiTest AIR Leak Tester Instruction Manual - cover page
Brand
DeFelsko
Category
Other device
Document type
User Manual
Language
English
Pages
33
File format
PDF
File size
1.1 MB
Published
24 November, 2023
Updated
24 November, 2023
MD5 checksum
7F3EEC1EAE556B973D5805BBAC58939D

About this manual

DeFelsko's PosiTest AIR Leak Tester is a portable, hand-operated instrument for testing air barrier integrity of single, two-ply, and liquid membrane systems, including air barriers, roofing systems, waterproofing, and ground liners, by locating leaks. It applies PosiTest AIR Test Solution to the test area, seals a transparent chamber over it, and depressurizes the chamber with a fan; bubbling of the solution indicates leak location and an estimate of relative leak size.

This instruction manual describes kit contents and test solution, preparation and cleaning, automatic and manual operating modes, test performance, result storage and download, power and charging, technical data, calibration, and return for service.

What's inside

  • Introduction
  • Quick Start
  • Preparing for the Test
  • Performing the Test
  • Power Supply / Low Battery Indicator
  • Technical Data
  • Calibration
  • Accessing Stored Test Results
  • Returning for Service

Specifications

ConformanceASTM E 1186 and others
Resolution1 Pa
Accuracy±(3% + 10 Pa)
PosiTest AIR storage temperature-22° to 149°F (-30° to 65°C)
PosiTest AIR operating temperature5° to 122°F (-15° to 50°C)
Test Solution storage temperature-22° to 149°F (-30° to 65°C)
Test Solution operating temperature-22° to 149°F (-30° to 65°C)
Power sourceBuilt-in rechargeable NiMH battery (>200 tests with full charge)
Charging time2-3 hours
Maximum pressure differential limit900 Pa
Maximum depressurization rate30 Pa/sec

Frequently asked questions

How many tests can the PosiTest AIR perform on a full battery charge?

More than 200 tests.

What standard does the PosiTest AIR conform to?

ASTM E 1186 and others.

How long does it take to charge the PosiTest AIR?

2 to 3 hours, depending on remaining battery power.

What indicates a leak during a test?

Bubbling of the test solution around the test area indicates a leak.