Grundfos MTH installation and operating instructions, describing the unpacking, installation and start-up information for the Grundfos MTH product, as well as important product information, service, troubleshooting and product disposal information.
This document serves as the installation and operating guide for the Grundfos MTH series of multi-stage centrifugal pumps. It covers safety warnings, mechanical and electrical installation procedures, startup steps, and operational guidelines. The manual is applicable to specific pump models including the MTH 2, MTH 4, MTH 8, MTH 10, and MTH 15. This manual is written in Chinese.
| Pump Type | Multi-stage centrifugal pump |
|---|---|
| Installation Orientation | Vertical only |
| Maximum Run Time with Closed Outlet Valve | 5 minutes |
| Motor Protection for >3.0 kW | Thermistor (PTC) |
No, the pump must be installed vertically.
Running the pump with the outlet valve closed for more than 5 minutes can cause damage due to internal high-temperature steam accumulation.
They are equipped with a thermistor (PTC) to prevent thermal overload.