The Dell Networking S5000 Getting Started Guide introduces the features and characteristics of the product.
The Dell S5000 is a 10G Top of Rack switch for converged LAN and SAN environments, with FCoE and Fibre Channel capability in a 1RU form factor. This guide covers unpacking, hardware installation, module and power supply placement, fan installation, port numbering, system LEDs, and initial network connection.
It also lists related S5000 documents and provides chassis, environmental, and power specifications, including dimensions, operating temperature, humidity, and power requirements.
| Height | 1.71 inches (43.5 mm) |
|---|---|
| Width | 17.4 inches (441 mm) |
| Depth | 28 inches (711 mm) |
| Chassis weight with factory-installed components | 34 pounds (approx.) (15.42 kg) |
| Operating temperature | 32° to 104°F (0° to 40°C) |
| Operating humidity | 10 to 85 percent (RH), noncondensing |
| Storage temperature | –40° to 158°F (–40° to 70°C) |
| Storage humidity | 5 to 95 percent (RH), noncondensing |
| Relative humidity | 10 to 85 percent, noncondensing |
| Maximum thermal output | 2388 BTU/hr |
| Maximum altitude | No performance degradation to 6600 ft |
| Shock | Meets Bellcore Zone 4 earthquake requirements |
| AC power supply | 100 VAC ~ 240 VAC 50/60 Hz |
| DC power supply | –48V ~ –60V VDC |
| Maximum current draw per system | 7 A @ 100 VAC; 3.5 A @ 200 VAC |
| Maximum power consumption | 700 Watts |
| Switching bandwidth | 640 Gbps |
| Fixed data ports | Four 40GbE QSFP+ ports |
The guide refers to hardware installation and power-up instructions, the FTOS Configuration Guide, the FTOS Command Line Reference Guide, and FTOS Release Notes.
A Fibre Channel module can be installed only in slot 0.
The S5000 supports two hot-swappable power supplies.
Maximum power consumption is 700 Watts.