400 series adjustable set point gas differential pressure switch, installation manual.
This operation manual describes installation and use of the 400.XX0/400.XX1 adjustable set point gas differential pressure switch. It covers switch body mounting, hose connection, electrical connection, testing, and installation drawings with dimensions.
The manual notes recommended vertical mounting with the air tubes pointing downward, horizontal mounting offsets, supplied hose dimensions, terminal functions, and a maximum working differential pressure of 7500 Pa. This manual is written in Chinese.
| Maximum working differential pressure | 7500 Pa |
|---|---|
| Supplied hose | 2 m long, 6.0 mm inner diameter |
| Screw diameter for ear-ring housing | 4.0 mm maximum |
| Screw diameter for U-bracket | 5.4 mm maximum |
| Electrical terminals | 1 common, 2 normally closed, 3 normally open |
Install it vertically with the air tubes pointing downward; the scale indication is accurate only in that position.
The maximum working differential pressure is 7500 Pa; exceeding it can damage the switch.
Terminal 1 is common, terminal 2 is normally closed, and terminal 3 is normally open.
A 2 m plastic hose with a 6.0 mm inner diameter is supplied.