This product is a digital DC current relay with over-current and under-current protection functions. The over-current and under-current setting range is the measurement range. The setting value and delay time are set through the panel keys. It can also be used as a digital DC ammeter or as a load control relay.
This manual describes a digital DC current relay with over-current and under-current protection. It can also be used as a digital DC ammeter or load control relay, supports automatic or manual reset, and captures maximum and minimum measured current values.
The document includes technical parameters, parameter settings and debugging steps, shunt configuration, terminal wiring, and a parameter setting example. Settings such as over-current value, under-current value, delay times, shunt rated current, shunt rated voltage drop, and reset mode are adjusted through the front-panel keys. This manual is written in Chinese.
| Measurement range (EIR-RDHL-5) | 0.00-5.00 A |
|---|---|
| Output relay capacity | 3 A/250 VAC or 3 A/30 VDC (resistive load) |
| Auxiliary power supply | 85-265 VAC or 110-360 VDC |
| Dimensions | 53 mm x 88 mm x 58 mm |
| Output relay contacts | 1 NO and 1 NC with common terminal |
When the measured current returns to a normal value, press the reset key to restore the output relay to its normal state.
The setting window displays "F", and the SET key must be pressed again to re-enter the settings.