TESCOM™ 44-6800E Series Electrically Heated Pressure Reducing Valves Safety Installation and Operating Instructions.
TESCOM 44-6800E series regulators are diaphragm-sensing pressure reducing regulators designed for reliable pressure regulation. They are intended for applications that reduce high system pressure, up to 6,000 psi, to a low pressure from 0 psig/0 bar to 500 psig/35 bar for instruments and related equipment. The evaporating regulator design can offset Joule-Thomson cooling that occurs during gas pressure reduction and can also be used in some applications to vaporize liquid into gas. A circuit board in the enclosure powers an electric heater that indirectly heats the process medium; the heater has a thermocouple for temperature feedback and a thermal cutoff (TCO) device.
This document provides safety, installation, operation, and maintenance instructions for the series. It lists operating parameters such as inlet and outlet pressure ratings, voltage, current, flow coefficient, heater temperature range, and ambient temperature limits, and describes installation precautions, regulator adjustment, heater temperature controller status, maintenance, certification, and warranty information. This manual is written in Chinese.
| Maximum inlet pressure (standard) | 3,500 psig / 241 bar / 24,132 kPa |
|---|---|
| Maximum inlet pressure (optional) | 6,000 psig / 414 bar / 41,368 kPa |
| Maximum outlet pressure | 500 psig / 34.5 bar / 3,448 kPa |
| Outlet pressure range | 0-25, 0-50, 0-100, 0-250, 0-500 psig; 0-17, 0-34, 0-69, 0-172, 0-345 bar; 0-172, 0-345, 0-690, 0-1724, 0-3448 kPa |
| Design pressure | 150% of maximum rated pressure |
| External leakage | Designed to meet helium leak ≤ 2x10^-8 atm cc/sec He |
| Supply voltage | 100-240 VAC, 50/60 Hz |
| Full-load current | 2.0 A at 240 VAC; 1.1 A at 120 VAC |
| Flow coefficient (Cv) | 0.02 (standard) |
| Heater temperature range | 122°F/50°C to 752°F/400°C |
| Maximum ambient temperature (electrical enclosure) | 149°F/65°C |
| Maximum ambient temperature (regulator body) | 185°F/85°C |
| Cable, cable gland, and wire temperature rating | Must exceed 95°C |
| Electrical enclosure mounting | Wrench-tightened, at least 5 full threads |
| 4-20 mA output temperature indication | 50-400°C / 122-752°F |
| Controller fuse | 3 A, 350 VAC |
| High system pressure capability | Up to 6,000 psi |
| Low pressure range | 0 psig/0 bar to 500 psig/35 bar |
The standard maximum inlet pressure is 3,500 psig (241 bar / 24,132 kPa), with an optional rating of 6,000 psig (414 bar / 41,368 kPa).
The heater temperature range is 122°F/50°C to 752°F/400°C.
No. The regulator is not a shutoff device; close the inlet supply when it is not in use and install relief downstream.
If the thermocouple fails and the analog output reading exceeds 25 mA, power to the heating element is no longer supplied; disconnect power and check the wiring.