This document introduces the installation, operation, maintenance and safety manual of low voltage flameproof motors.
This manual covers BBL low voltage flameproof motors certified for explosive atmospheres under ATEX/IECEx. It is intended for trained personnel and describes receipt, handling, storage, installation, commissioning, electrical connections, insulation resistance checks, thermal protection, and safety requirements.
It specifies storage conditions, lifting and handling precautions, ventilation clearances, cable entry and earthing practices, and conditions of use such as space heater and PTC thermistor operation. Repairs or refurbishment require referring to BBL.
| Storage temperature | 20 to 50 C |
|---|---|
| Storage relative humidity | 50% or less |
| Insulation resistance threshold | Lower than 10 mega ohms at 40 C requires drying |
| Winding dry-out condition | 130 C for at least 8 hours |
| Fan cover clearance | Minimum 50% of air inlet diameter |
| Fastening screws | High tensile carbon steel socket head cap screws, property class 8.8, minimum yield stress 640 MPa |
| Open bearing grease shelf life | 2 years (SKF LGMT3) |
| Shielded bearing storage life | 5 years |
All damage must be immediately photographed, documented, and reported to the transporter within 24 hours, and to the insurance company and BBL local office within 48 hours.
The storage room should be maintained at 20 to 50 C with relative humidity of 50% or less.
The winding must be dried out by heating it to 130 C for at least 8 hours.
High tensile carbon steel socket head cap screws of property class 8.8 with a minimum yield stress of 640 MPa.