The P20Z current or AC voltage transducer is a current or AC voltage transducer that can convert AC to DC.
The P20Z transducer converts RMS current or AC voltage without a constant component into a constant-current or constant-voltage standard signal. Its output signal is galvanically isolated from the input signal and supply, and the housing is made of plastic.
The manual covers installation on a 35 mm rail, external connection diagrams, technical data, execution codes, and maintenance and guarantee. The transducer does not require periodical maintenance.
| Input voltage | 60, 100, 150, 250, 400, 500, 600 V~ |
|---|---|
| Input current | 1 A (X/1 A~), 5 A (X/5 A~) |
| Output signal 0...5 mA | R load. £ 2000 W |
| Output signal 0...20 mA | R load. £ 500 W |
| Output signal 4...20 mA | R load. £ 500 W |
| Output signal 0...10 V | R load. 500 W |
| Response time | 0.3 sec |
| Accuracy class | 0.2 |
| Transducer preheating time | 15 min. |
| Consumption in supply circuit | £ 4 VA |
| Consumption in voltage circuit | £ 0.6 VA |
| Consumption in current circuit | £ 0.2 VA |
| Supply voltage | 85...253 V or 20...40 V d.c. or a.c. |
| Protection level by housing | IP 50 |
| Protection level from terminal side | IP 20 |
| Weight | 0.125 kg |
| Overall dimensions | 22.5 ´ 120 ´ 100 mm |
| Mounting | 35 mm rail |
| Maximal wire section, screw terminals | 2.5 mm2 |
| Maximal wire section, self-locking terminals | 1.5 mm2 |
| Input signal | 0...0.01...1.2 In; 0...0.01...1.2 Un |
| Frequency of input signal | 45...65...500 Hz |
| Rated supply | 85...253 V a.c., 90...300 V d.c.; 20...40 V a.c., 20...60 V d.c. |
| Admissible peak factor | current 2; voltage 2 |
| Ambient temperature | -20...23...55°C |
| Storage temperature | -25...+85°C |
| Relative humidity | 95% (inadmissible condensation) |
| External magnetic field | 0...40...400 A/m |
| Short-duration overload, voltage input | 2 Un (max. 1000 V) |
| Short-duration overload, current input | 10 In |
| Working position | any |
| Additional error from ambient temperature changes | < 0.5 k/10 K |
| Additional error from external magnetic field | < 1 k |
| Additional error from input signal frequency | < 1 k/100 Hz |
| EMC immunity | EN 61000-6-2 |
| EMC emission | EN 61000-6-4 |
| Safety standard | EN 61010-1 |
| Housing material | plastic |
| Output isolation | galvanically isolated from input and supply |
It converts RMS current or AC voltage without a constant component into a constant-current or constant-voltage standard signal.
No, it does not require any periodical maintenance.
It is adapted to be mounted on a 35 mm rail.
The accuracy class is 0.2.