This document is about how to use a digital multimeter.
This manual covers safety precautions, features, specifications, operation, battery replacement, case and accessory handling, and service and calibration for the Kyoritsu 3165/3166 insulation resistance tester.
It includes measurement procedures for insulation resistance and AC voltage, plus model-specific ranges, accuracy, overload protection, and physical specifications. This manual is written in Spanish.
| Test voltage | 500 V (Model 3165), 1000 V (Model 3166) |
|---|---|
| Insulation resistance range | 1000 MΩ (Model 3165), 2000 MΩ (Model 3166) |
| Mid-scale value | 20 MΩ (Model 3165), 50 MΩ (Model 3166) |
| Open-circuit output voltage | +20% / -0% of test voltage |
| Short-circuit output current | 230 µA max (Model 3165), 450 µA max (Model 3166) |
| Accuracy, 1-500 MΩ | ±5% of reading |
| Accuracy, 2-1000 MΩ | ±5% of reading |
| Accuracy, other ranges | ±0.7% of scale length |
| AC voltage warning range | 0-600 V AC |
| AC voltage warning accuracy | ±3% of scale length |
| Power source | 4 AA batteries or equivalent |
| Overload protection, insulation resistance range, Model 3165 | 600 V (DC + AC p-p) for 10 sec |
| Overload protection, insulation resistance range, Model 3166 | 1200 V (DC + AC p-p) for 10 sec |
| AC voltage range overload protection | 720 V (DC + AC p-p) for 10 sec |
| Operating temperature and humidity | 0-40°C, relative humidity 85% |
| Withstand voltage | 3700 V AC for one minute |
| Insulation resistance of housing | More than 50 MΩ at 1000 V |
| Dimensions | 90 x 137 x 40 mm |
| Weight | 330 g |
| Accessories | Test probes Mod. 7025 (1 set), probe pouch, strap, R6 batteries (4 pcs), manual |
It uses four 1.5 V AA (R6) batteries or equivalent.
It operates from 0 to 40°C with relative humidity up to 85%.
The insulation resistance range is protected for 600 V (DC + AC p-p) for 10 seconds.
The tester measures 90 x 137 x 40 mm and weighs 330 g.